English

AC/DC Reactor

AC/DC Reactor
AC/DC Reactor
prev
  • AC/DC Reactor
next
  • AC/DC Reactor
  • Country: China
  • Payment: L/C, D/P, T/T
  • Price: FOB, CIF
  • Inquire Online

Product Information

AC/DC Reactor
AC Reactors are intended for series connection in a system for limiting current or for load sharing purpose are available in wide range of current rating and inductance value.

DC Reactors to filter out harmonics present in DC power systems of high or low system voltages are available. Supressing harmonics of any frequency range with lesscore loss is an essence in our DC reactor design.

Features:-

Tailor made design to suit customer requirement
Single and Three Phase AC Reactors
Current upto 3000A, L value from uH to mH
Air Core / Iron Core Reactors
Linear Characteristics (unless customer requirement differs.)
Optimum Design
Rugged Construction Low Noise.
IP Series Enclosure (option) 


Operating environment
1)Temp.:The ambient temperature can not over +40℃。
2)Altitude: Mounting location can not exceed the altitude of 2000m
3)Relative humidity: Maximum 90%
4)The site not attack by rain and snow
5)The medium which no explosion danger, no corroding metal, no electrical breakdown

Testing Items:
No-load Test(No-load Current, No-load Voltage, No-load Loss)
Load Test (Load Voltage, Temperature-rise)
Inductive Voltage Test
DC Resistance Test
Safety Test

Productivity:
Toroidal/annular/ring transformer 2 million PCS,
EI transformer 3 million PCS annually;
Three Phase Transformer 50000pcs
Others 100000 pcs

Workforce:
About 200 workers, 5 technicians, 2 senior engineers

Equipment:
Over 50 sets toroidal/annular/ ring coil winding machines, 3 EI type transformer lines, 2 sets of vacuum annealing furnaces, A set of nitrogen and hydrogen production equipment.

Warning
Under no circumstances should both ends of the fixing bolt simultaneously contact the metal chassis or framework as this would create a potentially dangerous 'shorted-turn'.

Label Info:
Certificate Logo, Basic Electronic Data, Manufacture's Information, also can be printed according to customer's Advice.
Bar Code available according to customer's advice.

Certificate
The certificate of our transformer has CE CQC RoHs UL

Model
Power
(KW)
Rated Current
Inductance
(mH)
Voltage Drop
Insulation Class
Weight
(kg)
ACL-0005
1.5
5A
5.6
4%
F&H
2.8
ACL-0007
2.2
7A
3.5
4%
F&H
2.9
ACL-0010
3.7
10A
2.8
4%
F&H
4.0
ACL-0015
5.5
15A
1.9
4%
F&H
9.5
ACL-0020
7.5
20A
1.4
4%
F&H
9.6
ACL-0030
11
30A
0.93
4%
F&H
11.5
ACL-0040
15
40A
0.7
4%
F&H
12
ACL-0050
18.5
50A
0.56
4%
F&H
13
ACL-0060
22
60A
0.47
4%
F&H
13
ACL-0080
30
80A
0.35
4%
F&H
19
ACL-0090
37
90A
0.31
4%
F&H
22
ACL-0120
45
120A
0.23
4%
F&H
25
ACL-0150
55
150A
0.19
4%
F&H
27
ACL-0200
75
200A
0.14
4%
F&H
29
ACL-0250
110
250A
0.11
4%
F&H
32
ACL-0290
132
290A
0.096
4%
F&H
44
ACL-0330
160
330A
0.085
4%
F&H
44
ACL-0390
185
390A
0.072
4%
F&H
47
ACL-0490
220
490A
0.057
4%
F&H
70
ACL-0530
240
530A
0.053
4%
F&H
70
ACL-0600
280
600A
0.047
4%
F&H
77
ACL-0660
300
660A
0.042
4%
F&H
77
ACL-0800
380
800A
0.035
4%
F&H
Prev Next