Auto Transformer
We specialize in offering a wide range of Auto Transformer, which is also known as auto former. This Auto Transformer is an electrical transformer with only one winding that has at least three electrical connection points called taps. Our range of Autotransformer is fabricated using quality material to ensure high efficiency and trouble free service life.
Application usages:
Used for machines in which voltage ranges from 480 V supplies to a 600 V supply.
Used for providing conversions between the two common domestic mains voltage bands that range from 100-130 and 200-250
Used for 'Super Grid' networks that range from the UK 400kV to 275kV
Used for long rural power distribution lines in which the variable ratio of the auto transformer balances voltage drop along the line.
Tapped auto transformer is used in a speaker to regulate constant-voltage audio distribution system. In other words, it is used for impedance matching that varies from a low-impedance microphone to a high-impedance amplifier input
Features
Performs the same function as an isolation transformer of same KVA and voltage rating without the isolation feature
Ventilated openings in the enclosure are coordinated with the cooling ducts in the coils to ensure proper natural circulation of air for long life and minimum losses.
General purpose indoor ventilated steel enclosure suitable for dry locations. After fabrication, the enclosure is finished in ASA61 grey powder paint suitable for most industrial and commercial installations.
Most units have lifting lugs, conduit knockouts and removable front and back covers for easy access to terminals.
Basic Data :
Capacity: 100VA-200KVA
Phase: Single
Input: AC Power with Voltages of Various Countries
Output: AC Current, Voltage, According to Customers Requirements
Frequency: 50-60Hz
Voltage Regulation: 12%-3%
Manufacture Standard: GB/T15290-94, GB/19212-2006, GB2828-2829-87
Insulation Class: B, 130 Celsius Degree; E, 120 Celsius Degree
Temperature-rise: ≤85 Celsius Degree
Operating environment :
1)Temp.:The ambient temperature can not over +40℃。
2)Altitude: Mounting location can not exceed the altitude of 2000m
3)Relative humidity: Maximum 90%
4)The site not attack by rain and snow
5)The medium which no explosion danger, no corroding metal, no electrical breakdown
6)Environment exists with out gas,stem,chemical depostion,dust or dirt that will affact transformer insulation seriously,also explosive or corrosive medium is not allow
7)If any special working conditions that aqre not in line with above stipulations,user shall negotiate with us
Testing Items:
No-load Test(No-load Current, No-load Voltage, No-load Loss)
Load Test (Load Voltage, Temperature-rise)
Inductive Voltage Test
DC Resistance Test
Safety Test

| Model | Power(VA) | Model | Power(VA) | Out size(mm) | Install size(mm) | Install hole dia.(mm) | Weight | |||
| A | B | C | D | E | F | Kg | ||||
| DG-0.05 | 50 | D0G-0.1 | 100 | 77 | 65 | 72 | 63.5 | 51 | 4 | 1.45 |
| DG-0.06 | 60 | D0G-0.12 | 120 | 77 | 70 | 72 | 63.5 | 56 | 4 | 1.65 |
| DG-0.08 | 80 | D0G-15 | 150 | 77 | 77 | 72 | 63.5 | 63 | 4 | 1.9 |
| DG-0.1 | 100 | D0G-0.2 | 200 | 87 | 81 | 79 | 72 | 64 | 4.9 | 2.4 |
| DG-0.12 | 120 | D0G-0.25 | 250 | 87 | 86 | 79 | 72 | 69 | 4.9 | 2.6 |
| DG-0.15 | 150 | D0G-0.3 | 300 | 97 | 90 | 85 | 80 | 71 | 4.9 | 3 |
| DG-0.2 | 200 | D0G-0.4 | 400 | 97 | 95 | 85 | 80 | 76 | 4.9 | 3.4 |
| DG-0.25 | 250 | D0G-0.5 | 500 | 107 | 105 | 96 | 87.5 | 84 | 4.9 | 4.4 |
| DG-0.3 | 300 | D0G-0.6 | 600 | 115 | 108 | 102 | 95 | 82 | 4.9 | 5.1 |
| DG-0.4 | 400 | D0G-0.8 | 800 | 115 | 118 | 102 | 95 | 91 | 4.9 | 6 |
| DG-0.5 | 500 | D0G-1 | 1KVA | 135 | 121 | 117 | 111 | 88 | 5.8 | 7.4 |
| DG-0.6 | 600 | D0G-1.2 | 1.2KVA | 135 | 126 | 117 | 111 | 93 | 5.8 | 8.6 |
| DG-0.8 | 800 | D0G-1.5 | 1.5KVA | 135 | 136 | 117 | 111 | 103 | 5.8 | 9.8 |
| DG-1 | 1KVA | D0G-2 | 2KVA | 154 | 164 | 138 | 127 | 129 | 5.9 | 12 |
| DG-1.2 | 1.2KVA | D0G-2.5 | 2.5KVA | 154 | 184 | 138 | 127 | 149 | 5.9 | 18.5 |
| DG-1.5 | 1.5KVA | D0G-3 | 3KVA | 195 | 160 | 170 | 160 | 130 | 8.1 | 20 |
| DG-2 | 2KVA | D0G-4 | 4KVA | 195 | 170 | 170 | 160 | 140 | 8.1 | 22 |
| DG-2.5 | 2.5KVA | D0G-5 | 5KVA | 195 | 180 | 170 | 160 | 150 | 8.1 | 25 |
| DG-3 | 3KVA | D0G-6 | 6KVA | 232 | 185 | 210 | 190 | 138 | 8.1 | 30 |
| DG-4 | 4KVA | D0G-8 | 8KVA | 232 | 200 | 210 | 190 | 153 | 8.1 | 37 |
| DG-5 | 5KVA | D0G-10 | 10KVA | 232 | 215 | 210 | 190 | 168 | 8.1 | 41 |
| DG-6 | 6KVA | D0G-12 | 12KVA | 232 | 225 | 210 | 190 | 178 | 8.1 | 46 |
| DG-8 | 8KVA | D0G-15 | 15KVA | 310 | 235 | 265 | 170 | 145 | 12 | 64 |
| DG-10 | 10KVA | D0G-20 | 20KVA | 310 | 255 | 265 | 170 | 165 | 12 | 76 |
| DG-12 | 12KVA | D0G-25 | 25KVA | 310 | 265 | 265 | 170 | 175 | 12 | 83 |
| DG-15 | 15KVA | D0G-30 | 30KVA | 310 | 285 | 265 | 170 | 195 | 12 | 98 |
| DG-20 | 20KVA | D0G-40 | 40KVA | 360 | 295 | 310 | 200 | 205 | 12 | 135 |
| DG-25 | 25KVA | D0G-50 | 50KVA | 390 | 305 | 340 | 220 | 215 | 12 | 162 |
| DG-30 | 30KVA | D0G-60 | 60KVA | 390 | 320 | 340 | 220 | 230 | 12 | 175 |
| DG-40 | 40KVA | D0G-80 | 80KVA | 420 | 350 | 370 | 240 | 245 | 13 | 223 |
| DG-50 | 50KVA | D0G-100 | 100KVA | 440 | 310 | 450 | 275 | 205 | 13 | 265 |
| DG-60 | 60KVA | D0G-120 | 120KVA | 440 | 325 | 550 | 275 | 220 | 13 | 290 |
| DG-80 | 80KVA | D0G-150 | 150KVA | 480 | 350 | 550 | 300 | 245 | 14 | 370 |
| DG-100 | 100KVA | D0G-200 | 200KVA | 480 | 370 | 590 | 300 | 265 | 14 | 460 |
Productivity:
Toroidal/annular/ring transformer 2 million PCS,
EI transformer 3 million PCS annually;
Three Phase Transformer 50000pcs
Others 100000 pcs
Workforce:
About 200 workers, 5 technicians, 2 senior engineers
Equipment:
Over 50 sets toroidal/annular/ ring coil winding machines, 3 EI type transformer lines, 2 sets of vacuum annealing furnaces, A set of nitrogen and hydrogen production equipment.
Warning
Under no circumstances should both ends of the fixing bolt simultaneously contact the metal chassis or framework as this would create a potentially dangerous 'shorted-turn'.
Label Info:
Certificate Logo, Basic Electronic Data, Manufacture's Information, also can be printed according to customer's Advice.
Bar Code available according to customer's advice.
Certificate
The certificate of our transformer has CE CQC RoHs UL
Note
The above-mentioned single phase transformer is frequently-used, we can also manufacture the products by customer design. And the specification is for reference, if has the change further, please take the material object as the standard.