Single Phase Isolation Transformer
Single Phase Isolation Transformer defined: A transformer which isolates the primary circuit from the secondary circuit. An Isolation/distribution type Transformer should be used on all systems that require grounding of the load.
Single Phase isolation/distribution type transformers are ideal for supplying auxiliary lighting circuits from 600V and lower supplies and electric heating equipment.
Features :
General purpose indoor ventilated steel enclosure suitable for dry locations. After fabrication, the enclosure is finished in ASA61 grey powder paint suitable for most industrial and commercial installations.
Transformers up to 75KVA may be readily hung on H-columns, walls, shelves or floor mounted to suite each typical installation. Most units have lifting lugs, conduit knockouts and removable front and back covers for easy access to terminals.
Transformers larger than 75KVA are suitable for floor or platform mounting only.
Transformer terminations rated below 330A are supplied with suitable hardware and lugs for cable connection. Terminations above 330A are supplied with termination pads.
Basic Data :
Capacity: 50VA-100KVA
Phase: Single
Input: AC Power with Voltages of Various Countries
Output: AC Current, Voltage, According to Customers Requirements
Frequency: 50-60Hz
Voltage Regulation: 12%-3%
Manufacture Standard: GB/T15290-94, GB/19212-2006, GB2828-2829-87
Insulation Class: B, 130 Celsius Degree; E, 120 Celsius Degree
Temperature-rise: ≤85 Celsius Degree
Operating environment :
1)Temp.:The ambient temperature can not over +40℃。
2)Altitude: Mounting location can not exceed the altitude of 2000m
3)Relative humidity: Maximum 90%
4)The site not attack by rain and snow
5)The medium which no explosion danger, no corroding metal, no electrical breakdown
6)Environment exists with out gas,stem,chemical depostion,dust or dirt that will affact transformer insulation seriously,also explosive or corrosive medium is not allow
7)If any special working conditions that aqre not in line with above stipulations,user shall negotiate with us
Testing Items:
No-load Test(No-load Current, No-load Voltage, No-load Loss)
Load Test (Load Voltage, Temperature-rise)
Inductive Voltage Test
DC Resistance Test
Safety Test

| Model | Power(VA) | Model | Power(VA) | Out size(mm) | Install size(mm) | Install hole dia.(mm) | Weight | |||
| A | B | C | D | E | F | Kg | ||||
| DG-0.05 | 50 | D0G-0.1 | 100 | 77 | 65 | 72 | 63.5 | 51 | 4 | 1.45 |
| DG-0.06 | 60 | D0G-0.12 | 120 | 77 | 70 | 72 | 63.5 | 56 | 4 | 1.65 |
| DG-0.08 | 80 | D0G-15 | 150 | 77 | 77 | 72 | 63.5 | 63 | 4 | 1.9 |
| DG-0.1 | 100 | D0G-0.2 | 200 | 87 | 81 | 79 | 72 | 64 | 4.9 | 2.4 |
| DG-0.12 | 120 | D0G-0.25 | 250 | 87 | 86 | 79 | 72 | 69 | 4.9 | 2.6 |
| DG-0.15 | 150 | D0G-0.3 | 300 | 97 | 90 | 85 | 80 | 71 | 4.9 | 3 |
| DG-0.2 | 200 | D0G-0.4 | 400 | 97 | 95 | 85 | 80 | 76 | 4.9 | 3.4 |
| DG-0.25 | 250 | D0G-0.5 | 500 | 107 | 105 | 96 | 87.5 | 84 | 4.9 | 4.4 |
| DG-0.3 | 300 | D0G-0.6 | 600 | 115 | 108 | 102 | 95 | 82 | 4.9 | 5.1 |
| DG-0.4 | 400 | D0G-0.8 | 800 | 115 | 118 | 102 | 95 | 91 | 4.9 | 6 |
| DG-0.5 | 500 | D0G-1 | 1KVA | 135 | 121 | 117 | 111 | 88 | 5.8 | 7.4 |
| DG-0.6 | 600 | D0G-1.2 | 1.2KVA | 135 | 126 | 117 | 111 | 93 | 5.8 | 8.6 |
| DG-0.8 | 800 | D0G-1.5 | 1.5KVA | 135 | 136 | 117 | 111 | 103 | 5.8 | 9.8 |
| DG-1 | 1KVA | D0G-2 | 2KVA | 154 | 164 | 138 | 127 | 129 | 5.9 | 12 |
| DG-1.2 | 1.2KVA | D0G-2.5 | 2.5KVA | 154 | 184 | 138 | 127 | 149 | 5.9 | 18.5 |
| DG-1.5 | 1.5KVA | D0G-3 | 3KVA | 195 | 160 | 170 | 160 | 130 | 8.1 | 20 |
| DG-2 | 2KVA | D0G-4 | 4KVA | 195 | 170 | 170 | 160 | 140 | 8.1 | 22 |
| DG-2.5 | 2.5KVA | D0G-5 | 5KVA | 195 | 180 | 170 | 160 | 150 | 8.1 | 25 |
| DG-3 | 3KVA | D0G-6 | 6KVA | 232 | 185 | 210 | 190 | 138 | 8.1 | 30 |
| DG-4 | 4KVA | D0G-8 | 8KVA | 232 | 200 | 210 | 190 | 153 | 8.1 | 37 |
| DG-5 | 5KVA | D0G-10 | 10KVA | 232 | 215 | 210 | 190 | 168 | 8.1 | 41 |
| DG-6 | 6KVA | D0G-12 | 12KVA | 232 | 225 | 210 | 190 | 178 | 8.1 | 46 |
| DG-8 | 8KVA | D0G-15 | 15KVA | 310 | 235 | 265 | 170 | 145 | 12 | 64 |
| DG-10 | 10KVA | D0G-20 | 20KVA | 310 | 255 | 265 | 170 | 165 | 12 | 76 |
| DG-12 | 12KVA | D0G-25 | 25KVA | 310 | 265 | 265 | 170 | 175 | 12 | 83 |
| DG-15 | 15KVA | D0G-30 | 30KVA | 310 | 285 | 265 | 170 | 195 | 12 | 98 |
| DG-20 | 20KVA | D0G-40 | 40KVA | 360 | 295 | 310 | 200 | 205 | 12 | 135 |
| DG-25 | 25KVA | D0G-50 | 50KVA | 390 | 305 | 340 | 220 | 215 | 12 | 162 |
| DG-30 | 30KVA | D0G-60 | 60KVA | 390 | 320 | 340 | 220 | 230 | 12 | 175 |
| DG-40 | 40KVA | D0G-80 | 80KVA | 420 | 350 | 370 | 240 | 245 | 13 | 223 |
| DG-50 | 50KVA | D0G-100 | 100KVA | 440 | 310 | 450 | 275 | 205 | 13 | 265 |
| DG-60 | 60KVA | D0G-120 | 120KVA | 440 | 325 | 550 | 275 | 220 | 13 | 290 |
| DG-80 | 80KVA | D0G-150 | 150KVA | 480 | 350 | 550 | 300 | 245 | 14 | 370 |
| DG-100 | 100KVA | D0G-200 | 200KVA | 480 | 370 | 590 | 300 | 265 | 14 | 460 |
Comparison on Transformer with Toroidal, EI, R, CD Shape Core
Since 1995, we have been playing a leading role to replace the types of R, CD, EI with toroidal type for our customers from each part of the world.
Core EI, R & CD Toroidal
Dimension Not Adjustable Adjustable
Performance Average Better
Reliability Average Better
Price Expensive 10%-30% Cost Saved
Productivity:
Toroidal/annular/ring transformer 2 million PCS,
EI transformer 3 million PCS annually;
Three Phase Transformer 50000pcs
Others 100000 pcs
Workforce:
About 200 workers, 5 technicians, 2 senior engineers
Equipment:
Over 50 sets toroidal/annular/ ring coil winding machines, 3 EI type transformer lines, 2 sets of vacuum annealing furnaces, A set of nitrogen and hydrogen production equipment.
Warning
Under no circumstances should both ends of the fixing bolt simultaneously contact the metal chassis or framework as this would create a potentially dangerous 'shorted-turn'.
Label Info:
Certificate Logo, Basic Electronic Data, Manufacture's Information, also can be printed according to customer's Advice.
Bar Code available according to customer's advice.
Certificate
The certificate of our transformer has CE CQC RoHs UL
Note
The above-mentioned single phase Isolation transformer is frequently-used, we can also manufacture the products by customer design. And the specification is for reference, if has the change further, please take the material object as the standard.