Product Information

Single Phase Isolation Transformer
Isolation Transformers have primary and secondary windings that are physically separated from each other. Sometimes isolation transformers are referred to as "insulated".
This is because the windings are insulated from each other. In an isolation transformer the output winding will be isolated, or floating from earth ground unless bonded at the time of installation. Secondary neutral to ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground reference for sensitive equipment and an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades.

Application:
This single phase isolation transformer is widly applied to the single phase power supply of import-export equipment,safe-isolation power supply,step up-step down power supply,rectifier equipment power supply,detecting system power supply,and kinds of machinery power supply.(The mode of connection can select lead wire,raw copper wire,connection,brass screw of input and output voltage is less than 1000V)

Basic Data
Primary/Secondary Voltage:220/220V  220-380V
Rated Power : 50VA-100KvA
Rated Frequency:50/60Hz
Cooling method:naturel air or forced air cooling
Ambinet temperaturer:-50 to 40 Celsius Degree
Isoaltion systerm : B ,F , H

Operating environment
1)Temp.:The ambient temperature can not over +40℃。
2)Altitude: Mounting location can not exceed the altitude of 2000m
3)Relative humidity: Maximum 90%
4)The site not attack by rain and snow
5)The medium which no explosion danger, no corroding metal, no electrical breakdown

Testing Items:
No-load Test(No-load Current, No-load Voltage, No-load Loss)
Load Test (Load Voltage, Temperature-rise)
Inductive Voltage Test
DC Resistance Test
Safety Test

 

Model Power(VA) Model Power(VA) Out size(mm) Install size(mm)  Install hole dia.(mm) Weight 
 A B C D E F Kg 
DG-0.05 50 D0G-0.1 100 77 65  72 63.5  51 4  1.45
DG-0.06 60 D0G-0.12 120 77 70  72  63.5 56 4  1.65
DG-0.08 80 D0G-15 150 77 77 72 63.5 63 4  1.9
DG-0.1 100 D0G-0.2 200 87 81 79 72 64 4.9  2.4
DG-0.12 120 D0G-0.25 250 87 86 79 72 69 4.9  2.6
DG-0.15  150 D0G-0.3 300 97 90 85 80 71 4.9  3
DG-0.2 200 D0G-0.4 400 97 95 85 80 76 4.9  3.4
DG-0.25 250 D0G-0.5 500 107 105 96 87.5 84 4.9  4.4
DG-0.3 300 D0G-0.6 600 115 108  102  95 82 4.9  5.1
DG-0.4 400 D0G-0.8 800 115 118  102  95 91 4.9  6
DG-0.5 500 D0G-1 1KVA 135 121 117  111 88 5.8  7.4
DG-0.6 600 D0G-1.2 1.2KVA 135 126 117  111 93 5.8  8.6
DG-0.8 800 D0G-1.5 1.5KVA 135 136 117  111 103 5.8  9.8
DG-1 1KVA D0G-2 2KVA 154 164 138   127 129 5.9  12
DG-1.2 1.2KVA D0G-2.5 2.5KVA 154 184 138  127 149 5.9  18.5
DG-1.5 1.5KVA D0G-3 3KVA 195 160 170  160 130  8.1  20
DG-2 2KVA D0G-4 4KVA 195 170 170  160 140  8.1  22
DG-2.5 2.5KVA D0G-5 5KVA 195 180 170  160 150  8.1  25
DG-3 3KVA D0G-6 6KVA 232 185  210  190 138  8.1  30
DG-4 4KVA D0G-8 8KVA 232 200  210  190 153  8.1  37
DG-5 5KVA D0G-10 10KVA 232 215  210  190 168  8.1  41
DG-6 6KVA D0G-12 12KVA 232 225 210  190 178  8.1  46
DG-8 8KVA D0G-15 15KVA 310 235 265  170 145 12  64
DG-10 10KVA D0G-20 20KVA 310 255 265  170 165 12  76
DG-12 12KVA D0G-25 25KVA 310 265 265  170 175 12  83
DG-15 15KVA D0G-30 30KVA 310 285 265  170 195 12  98
DG-20 20KVA D0G-40 40KVA 360 295 310  200 205 12  135
DG-25 25KVA D0G-50 50KVA 390 305 340  220 215 12  162
DG-30 30KVA D0G-60 60KVA 390 320 340 220  230 12  175
DG-40 40KVA D0G-80 80KVA 420 350 370 240 245 13  223
DG-50 50KVA D0G-100 100KVA 440 310 450 275 205 13  265
DG-60 60KVA D0G-120 120KVA 440 325 550 275 220 13  290
DG-80 80KVA D0G-150 150KVA 480 350 550 300 245 14  370
DG-100 100KVA D0G-200 200KVA 480 370 590 300 265 14  460

Comparison on Transformer with Toroidal, EI, R, CD Shape Core
Since 1995, we have been playing a leading role to replace the types of R, CD, EI with toroidal type for our customers from each part of the world.
Core EI, R & CD Toroidal
Dimension Not Adjustable Adjustable
Performance Average Better
Reliability Average Better
Price Expensive 10%-30% Cost Saved

Productivity:
Toroidal/annular/ring transformer 2 million PCS,
EI transformer 3 million PCS annually;
Three Phase Transformer 50000pcs
Others 100000 pcs

Workforce:
About 200 workers, 5 technicians, 2 senior engineers

Equipment:
Over 50 sets toroidal/annular/ ring coil winding machines, 3 EI type transformer lines, 2 sets of vacuum annealing furnaces, A set of nitrogen and hydrogen production equipment.

Warning
Under no circumstances should both ends of the fixing bolt simultaneously contact the metal chassis or framework as this would create a potentially dangerous 'shorted-turn'.

Label Info:
Certificate Logo, Basic Electronic Data, Manufacture's Information, also can be printed according to customer's Advice.
Bar Code available according to customer's advice.

Certificate:
The certificate of our transformer has CE CQC RoHs UL

Note:
The above-mentioned single phase Isolation transformer is frequently-used, we can also manufacture the products by customer design. And the specification is for reference, if has the change further, please take the material object as the standard.

 