120W Quald Output Switching Power Supply
Feature:
AC Input Range Selectable By Switch
Low Cost,High Reliability
Low Power Consumption
Built-in EMI Filter
Protections: Over Load/Short Circuit
100% Full Load High Temperature Burn-in Test
Specification :
Input Voltage Range : 88-132VAC/176-264VAC Selectable By Switch
Input Frequency : 47-63Hz
Inrush Current : Cold Start,30A/115VAC,50A/230VAC
Output Adjustment Range : CH1:-5%-+10% Rated Output Voltage
Line Regulation : ≤0.5
Output Over Load Protection: 105%-135% Shut Off,AC Recycle To Re-Start
Output Short Circuit Protection: Shut Off,AC Recycle To Re-Start
Rise,Hold Up Time : 50mS,20mS at full Load (Typical)
Hip-pot Isolation : I/P-O/P 3KVAC ,I/P-FG 1.5KVAC ,OP/FG 0.5KVAC
Operating Temperature Range : 0℃ to 50 ℃ @100%,-10℃@80%,+60℃@60% Load
Storage Temperature Range : -40℃ to +85℃ ,0 to 95%RH (Non-Condensing)
Safety Standards : Design Refer To UL 1012
EMC Standard :Design Refer To FCC Part 15J
Cooling Method : Free Air Cooling Convection
Weight : 0.85Kg/pcs
Note:
1 All dimensions in mm
2 Tolerance (except cable length) : ××=±0.04
××=±0.010
Products Model
|
DC Output
|
Load regul.
|
R&N
|
Efficincy
|
Max Output
|
HTQ-120-A
|
5V, 2-12A
|
1%
|
100mV
|
76%
|
120W
|
12V,0.5-5A
|
6%
|
120mV
|
-5V,0.2-1A
|
6%
|
100mV
|
-12V-0-1A
|
6%
|
120mA
|
HTQ-120-B
|
5V,2-12A
|
1%
|
100mV
|
75%
|
123W
|
12V,0.2-5A
|
6%
|
120mV
|
24V,0 -1A
|
6%
|
100mV
|
-15V,0.2-1A
|
+10%,-5%
|
120mV
|
HTQ-120-C
|
5V,2-12A
|
1%
|
100mV
|
79%
|
124W
|
12V,0.2-5A
|
6%
|
120mV
|
24V,0.2-2A
|
6%
|
150mV
|
-12v,0.2-1A
|
6%
|
120mV
|