Characteristics:
1.Compared with EI shapes,R type transformer is smaller 30%, thiner 40% than EI type transformer.
2.R type transformer is the lease of leakage magnetic. Less10 times than EI-Type transformer.
3.R type transformer make the least heat, less 50% than EI type.
4.R type transformer has no noise, that is more better than other type transformers.
5.Compared with toroidal transformer, R type transformer has more advantage, such as powerful function, more reliability, better insulation and easy to install.
6.Compared with EI type and C type, the structure is more simple but the reliability and quality are more better than them.
7.R type transformer can reduce your cost and increase the efficiency.
8.The design of R type transformer can be satisfied all safe standard in the world.
Application :
Monitor, printer, computer terminals, photocopier, fax machine, Digital satellite and broadcast receiver, High fidelity acoustics megaphone, survey equipment and test equipment, Electrical Equipment and supplies, metrologic instrument, ED Electron Device usde for medical, financial instrument, Industrial equipment, signalling equipment, monitior warning facility, communication equipment, lift and so on.
Testing Items:
No-load Test(No-load Current, No-load Voltage, No-load Loss)
Load Test (Load Voltage, Temperature-rise)
Inductive Voltage Test
DC Resistance Test
Safety Test
Operating environment
1)Temp.:The ambient temperature can not over +40℃。
2)Altitude: Mounting location can not exceed the altitude of 2000m
3)Relative humidity: Maximum 90%
4)The site not attack by rain and snow
5)The medium which no explosion danger,no corroding metal,no electrical breakdown
Certificate
The certificate of our transfomer has CE CQC RoHs UL
Label Info:
Certificate Logo, Basic Electronic Data, Manufacture's Information,also can be printed according to customer's Advice
Note
The above-mentioned products is frequently-used,we can also manufacture the products by customer design.And the specification is for reference,If has the change futher,please take the material object as the standard.

Model |
Power(VA) |
Out size and install size(mm) |
Weight |
A |
B |
C |
D |
E |
Kg |
R5 |
2-6 |
57 |
47 |
27 |
45 |
33 |
0.2 |
R8 |
7-10 |
69 |
61 |
34 |
53 |
44 |
0.3 |
R10 |
11-15 |
74 |
61 |
37 |
68 |
48 |
0.4 |
R20 |
15-25 |
80 |
70 |
39 |
55 |
45 |
0.5 |
R30 |
25-40 |
96 |
77 |
42 |
70 |
60 |
0.7 |
R40 |
40-55 |
99 |
80 |
44 |
70 |
60 |
0.9 |
R50 |
55-65 |
101 |
92 |
48 |
75 |
65 |
1.0 |
R65 |
65-80 |
105 |
95 |
51 |
90 |
65 |
1.2 |
R80 |
80-100 |
125 |
90 |
52 |
90 |
70 |
1.4 |
R100 |
100-120 |
126 |
110 |
57 |
100 |
80 |
1.7 |
R160 |
120-200 |
138 |
115 |
63 |
100 |
85 |
2.5 |
R260 |
200-280 |
160 |
121 |
66 |
130 |
95 |
3.4 |
R320 |
280-380 |
163 |
128 |
70 |
135 |
95 |
3.8 |
R600 |
380-600 |
185 |
150 |
83 |
142 |
100 |
6.3 |
R1000 |
600-1000 |
225 |
185 |
97 |
180 |
140 |
10.0 |